Clinics in Orthopedic Surgery ; : 321-324, 2012.
Article in English | WPRIM | ID: wpr-15280

ABSTRACT

Fixation of proximal humerus fractures with precontoured, fixed angle devices has improved operative management of these difficult injuries, particularly in patients with osteoporosis. However, recent data has revealed that fixation with these constructs is not without complications, particularly screw cut-out and loss of reduction. Multiple strategies have been developed to decrease the number of complications. We offer a surgical technique combining suture augmentation of the proximal humerus with locked plate fixation utilizing short screws.


Subject(s)
Humans , Bone Plates , Bone Screws , Fracture Fixation/instrumentation , Shoulder Fractures/rehabilitation